
ACCUTREND Plus Cholesterol, triglycerides and lactate levels test mg/dl
Pack size:1 pc
Accutrend Plus device mg/dl
Safe and reliable readings
- Accuracy and precision across the entire measuring range
- Performance and instrumentation checks are carried out automatically
- Stores up to 100 measured values
User-friendly and comfortable
- User-friendly storage function
- Store the test strips at room temperature
The Accutrend Plus from Roche is a blood analysis device for determining cholesterol, triglycerides and lactate levels
The Accutrend® Plus System is a flexible, handheld point-of-care device for determining three key cardiometabolic parameters and lactate levels. The system is intended for use in physician's offices and hospitals, as well as for self-monitoring at home under medical supervision and during exercise. The measurement requires only a small amount of capillary blood.
Safe and reliable measured values
- High accuracy and precision across the entire measuring range for all parameters
- Automatic performance and measuring device controls
- Barcodes for batch-specific calibration data with positive batch and parameter identification
User-friendly and comfortable
- Convenient determination of parameters from just one drop of capillary blood
- Store the test strips at room temperature
- User-friendly storage function for reliable monitoring
Product features
-
Convenient determination of
- Cholesterol,
- Triglycerides,
- Glucose and
- Lactate with proven test strip technology from capillary blood
- Time to measurement results: Cholesterol in 180 seconds, triglycerides in 174 seconds, glucose in 12 seconds and lactate in 60 seconds
- Automatic performance and device self-check – code strips with positive strip identification and parameter recognition
- Store the test strips at room temperature
- Storage of up to 100 measured values per parameter with date, time and other characteristics
- High precision and accuracy across the entire measuring range for all parameters
The permissible temperature for measurement depends on the parameter to be determined:
Glucose: 18 °C to 32 °C
Cholesterol: 18 °C to 35 °C
Triglycerides: 18 °C to 30 °C
Lactate: 15 °C to 35 °C
Measuring ranges:
Blood glucose: 20 to 600 mg/dl (1.1 to 33.3 mmol/l)
Cholesterol: 150 to 300 mg/dl (3.88 to 7.76 mmol/l)
Triglycerides: 70 to 600 mg/dl (0.80 to 6.86 mmol/l)
Lactate: 0.8 to 21.7 mmol/l (whole blood), 0.7 to 26 mmol/l (plasma)
Storage temperature (blood glucose meter) : -25 °C to +70 °C
Relative humidity: 10% to 85% (without condensation)
Sample material: 1 drop of fresh capillary blood
Storage capacity: 100 measured values, optionally with date, time and additional information for each parameter
Test principle: Reflectance photometry
Dimensions: 154 mm x 81 mm x 30 mm
Weight: 140 g (without batteries) Automatic switch-off after two minutes without pressing a button
Power supply: 1.5 V AAA alkaline manganese batteries (4 pieces) allow more than 1,000 measurements, protection class III
Scope of delivery:
-
Accutrend® Plus System
-
suitable batteries
- User manual